C200H-CP114 - Cam positionner module - OMRON
This camera positioning module of OMRON brand and reference C200H-CP114 belongs to the range CS1.
Module: 48 cam outputs (16 external outputs, 32 internal). Resolver speed: 20 ms (5 Khz)
This output module C200H-OC226N is available to replace your defective hardware and has a warranty adapted to your needs.
The Cam Positioner Unit detects angles of rotation by means of a connected resolver and provides cam outputs with preset ON/OFF angle data.
A maximum of 48 cam outputs (16 internal/external and 32 internal) are avail- able.
A maximum of seven ON/OFF data items can be set for a single cam output.
A maximum of eight banks of cam data can be present, with each bank con- sisting of 48 cam outputs.
A bank can be selected from the C200H by means of either a peripheral tool such as the Programming Console or the C200H user’s program.
Any OMRON-made resolver can be used.
To connect a resolver to the Cam Positioner Unit, use the 20-cm-long auxiliary connection cable that is provided. When using a resolver with no cable attached, prepare a cable for the resolver.
Responds at a maximum angle-detecting cycle of 200 μs (with a sampling fre- quency of 5 kHz) and at a maximum resolver speed of 800 revolutions per minute.
An angle unit of 1° is used for cam output control (resolver resolution).
For inputting data, displaying present values, and so on, use the C200H-
DSC01 Data Setting Console (sold separately).
The display is easy to read and can be panel-mounted.
Data can also be set by means of the C200H user’s program.
ON/OFF data can be set or altered by actually moving the machine.
Origin adjustment is possible with either the origin adjustment switch on the front panel of the Cam Positioner Unit or an Origin Adjustment Flag. (Origin adjustment matches the resolver origin with the mechanical origin.)
After debugging and trial operation, the final ON/OFF cam output data can be protected.
To protect the data, set the protect setting pin to “permitted” and make the set- ting with the Data Setting Console.
Independent protection is possible for each bank and cam output.
It is possible to set cam ON/OFF data and required revolution data for a single process via the C200H (using a peripheral tool such as the Programming Console, or the user’s program).
Omron was created by Kazuma Tateish in 1933. Based in Kyoto, Japan, Omron Corporation is a global leader in automation. Headed by President Yoshihito Yamada, Omron has approximately 37,000 employees in more than 36 countries who offer products and services in various areas, including automation components and systems, electronic components and medical and paramedical products.