890CS5-0054B-B - Power module - PARKER
This reference power supply module 890CS5-0054B-B and brand PARKER is a module of the AC890 series.
890CS5-0054B-B: Input: 54A, 230/400/500Vac, 15/30/37kW. Output: DC, 65A
This PARKER power supply is at your disposal to replace your defective equipment and has an appropriate guarantee.
New part number: 890CS-532540B0-000-U
DESCRIPTION
Modular, the AC890 series is designed to adapt exactly to your needs; it comprises: - 890CD inverter modules supplied with DC voltage and each controlling a motor - 890CS dual-output power supply modules delivering DC voltage to supply one or more 890CD inverters or 890SD stand alone drives connected on a common DC bus. This modularity saves a lot of space in the cabinet
Power supply 890CS From 40 to 200A
Power supply 208-500Vac
Integrated dynamic braking module
Double DC bus power supply output on terminal block and busbar
Diagnostic operator screen
KEY POINTS of the 890CS Power Module
- "Drive ready" contact
- 24Vdc auxiliary power supply (optional)
- HMI link interface
- Three-phase power selector
- Configurable analog outputs
- Pre-alarm output
DESCRIPTION
The AC890 series corresponds to a range of system drives specially designed for industrial applications, in the field of servo or vector control. Its unique control loop allows the control of asynchronous motors and brushless motors. The V/F, sensorless or flux vector control mode is dedicated to the control of asynchronous motors while the servo control mode allows the control of permanent magnet brushless motors. In addition to its modularity and its 5 control modes, the AC890 is compatible with the majority of field buses, including FireWire 1394. Most speed/position sensors can be used: resolver, HTTL encoder, SinCos, EnDat. DSE programming software simplifies setup and diagnostics.
5-mode drive: v/f, vector without encoder feedback, flux vector, servo, network regeneration (AFE)
Integrated EMC filters
2 Performance Levels (Advanced, High Performance)
Safety option Safe Stop EN954-1 Cat3
Fieldbus: Profibus, DeviceNet, ControlNet, CANOpen
STANDALONE or common power bus versions
890CS/CD Common Bus version
The AC890 Common Bus solution consists of a power supply module and drive modules connected together via a DC power supply bus. The power of the drive modules is between 0.75 and 90kW, with sizes varying according to the power required.
Standalone 890SD
The AC890 drive is supplied directly from the network with voltages between 230 and 480Vac and power ranges from 0.25 to 1000kW. Different sizes are available depending on the power required.
TECHNICAL SPECIFICATIONS
Food
890CS: 208÷500Vac ± 10%
890CD: 320/560÷705Vdc
890SD: 380÷500Vac ±10% (E/F/G/H/J/K sizes: 380÷460Vac ±10%)
Temperature:
0 to 45°C
Derating 2%/°C up to 50°C max Sizes G/H/J/K: 0÷40°C
Maximum relative humidity:
85% non-condensing
Altitude:
max. 1000m
Derating 1%/100m between 1000 and 4000m max)
Degree of protection:
IP20 (G/H/J/K sizes: IP00)
Entries exits:
Analog inputs: 4 configurable including 2 (0-10V, ±10V, 0-20mA, 4-20mA) and 2 (0-10V, ±10V)
Analog outputs: 2 configurable (0-10V, ±10V)
Discrete inputs: 7 configurable (24V)
Digital inputs/outputs: 2 configurable (24V)
Relay output: 1 configurable
Fieldbus:
Profibus, DeviceNet, ControlNet, CANopen
Axis synchronization via high-speed Firewire bus
Founded in 1918, the Parker Appliance Company has evolved into Parker Hannifin Corporation, reflecting a legacy of innovation. We believe that our future development is assured if we respect Parker's tradition of excellence.